Maximum output for I-position control (P-AXIS-00496)
| P-AXIS-00496 | Maximum output for I-position control | |
| Description | The actuating value output by the I-position controller can be limited. The limit value is specified in 0.1% of the maximum permissible axis velocity (P-AXIS-00212). When the maximum value is overshot, the error message P-ERR-110576 is output and the value is corrected to 1000. | |
| Parameter | getriebe[i].integral_limit | |
| Data type | UNS16 | |
| Data range | 0 ≤ integral_linit ≤ 1000 | |
| Axis types | T, R, S | |
| Dimension | T: 0.1% | R,S: 0.1% | 
| Default value | 100 | |
| Drive types | ---- | |
| Remarks | 
 | |