Filtering of sensor values (P-AXIS-00413)

P-AXIS-00413

Filtering of sensor values (spindle with touch probe)

Description

In some cases, the sensor values are noisy. To keep excitation of the machine low, the setpoints for distance control can be smoothed via a filter. The parameter indicates the number of values for filtering.

Parameter

kenngr.distc.n_cycles

Data type

SGN32

Data range

0 ≤ n_cycles < 100

Axis types

T, R

Dimension

T: ----

R: ----

Default value

4

Drive types

SERCOS, Profidrive, CANopen

Remarks