Suppress stop of spindle axis during channel reset (P-AXIS-00455)
| P-AXIS-00455 | Suppress stop of spindle axis during channel reset | |
| Description | By default a spindle axis which is commanded by M3, M4 or M19 is stopped during channel reset. The stop of the spindle axis can be suppressed by setting this parameter to 1 (TRUE). | |
| Parameter | kenngr.no_stop_by_channel_reset | |
| Data type | BOOLEAN | |
| Data range | 0/1 | |
| Axis types | S | |
| Dimension | 
 | S: ---- | 
| Default value | 0 | |
| Drive types | ---- | |
| Remarks | 
 | |