Average value filter for current master velocity (P-AXIS-00300)
| P-AXIS-00300 | Average value filter for current master velocity for camming / gearing | |
| Description | This parameter activates the arithmetic average value filter for the mast actual velocity. This parameter is used for gearing at the current master velocity. | |
| Parameter | cam_gear.mv_type | |
| Data type | UNS16 | |
| Data range | 0/1 | |
| Axis types | T, R, S | |
| Dimension | T: ---- | R,S: ---- | 
| Default value | 0 | |
| Drive types | ---- | |
| Remarks | 
 | |