ID 22263

#SYNC OUT with selected coordinate system is not allowed.

Description

When the Conveyor tracking [FCT-M4] function was used, desynchronisation was programmed using the #SYNC OUT command with an active coordinate system. This is not permitted.

Example with error:

N010 #CS DEF [1][1,15,5,20,30,45] (CS definition)

N020 #SYNC IN

N030 #CS ON[1]    (enable the CS with ID 1)

; …

N090 #SYNC OFF

N100 #CS OFF    (deselect the CS )

; …

 

Corrected example:

N010 #CS DEF [1][1,15,5,20,30,45] (CS definition)

N020 #SYNC IN

N030 #CS ON[1]    (enable the CS with ID 1)

; …

N090 #CS OFF    (deselect the CS )

N100 #SYNC OFF

; …

Response

Class

2

Abort NC program processing.

Solution

Class

3

Check and modify the NC program; change the command sequence.

Error type

1, Error message from NC program.