Number of cycles for ‘smooth switching’ (P-COMP-00027)
| P-COMP-00027 | Number of cycles for ‘smooth switching’ | |
| Description | This parameter determines the number of cycles for which plane compensation is activated/deactivated smoothly. | |
| Parameter | kw.crosscomp2.n_cycles | |
| Data type | UNS16 | |
| Data range | 0 ≤ n_cycles ≤ 20 (maximum number of cycles for which cross compensation is activated/deactivated, | |
| Axis types | T, R, S | |
| Dimension | T: ---- | R,S: ---- | 
| Default value | 0 | |
| Remarks | 
 | |