ID 292085
| Couple kinematics: All groups are configured with group ID 0. | ||||
| Description | All groups in a couple kinematic have the ID 0 (P-CHAN-00447). 
 Incorrect configuration trafo[0].id 1 trafo[0].type 45 … trafo[1].id 2 trafo[1].type 91 … trafo[2].id 3 trafo[2].type 210 trafo[2].group[0].id 0 trafo[2].group[0].workpiece_cs 200 trafo[2].group[0].chain[0] 1 trafo[2].group[1].id 0 trafo[2].group[1].chain[0] 2 
 Corrected entries: trafo[2].group[0].id 100 … trafo[2].group[0].id 200 | |||
| Response | Class | 2 | Abort NC program processing. | |
| Solution | Class | 3 | Check and modify the configuration of the couple kinematic.  | |
| Parameter | %1: | Current value [-] | ||
| ID of incorrectly configured kinematic,  | ||||
| %2: | Error value [-] | |||
| Internal ID of error cause (only for diagnosis by specialists) | ||||
| Error type | - | |||
| 
 | ||||