ID 70648
| Configured detection torque exceeds the maximum torque when referencing to fixed stop. | ||||
| Description | The detection torque is greater than the maximum torque that was configured for homing to a fixed stop. | |||
| Response | Class | 1 | Warning output and value corrected to the maximum torque during homing to a fixed stop. | |
| Solution | Class | 1 | Set value smaller than 1000 for P-AXIS-00347. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number (P-AXIS-00016) of affected axis | ||||
| %2: | Current value [0.1%] | |||
| Parameterised detection torque. | ||||
| %3: | Upper limit value [-] | |||
| Parameterised torque for homing to a fixed stop. | ||||
| %4: | Corrected value | |||
| Corrected detection torque | ||||
| Error type | 11, Error message from position controller. | |||
| 
 | ||||