ID 110681
| Invalid value for inverse rotation direction for spindle P-AXIS-00490 . | ||||
| Description | The spindle rotation direction can be inverted for various functions by using P-AXIS-00490. An invalid parameter was assigned to this parameter. | |||
| Response | Class | 1 | Warning and correction of parameter. P-AXIS-00490 is set to FALSE. | |
| Solution | Class | 1 | Check P-AXIS-00490. Use a valid value. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number P-AXIS-00016 of axis affected | ||||
| %2: | Current value [-] | |||
| Current hexadecimal value of parameter P-AXIS-00490 | ||||
| %3: | Upper limit value [-] | |||
| Maximum limit of parameter P-AXIS-00490 | ||||
| %4: | Corrected value [-] | |||
| Corrected value of parameter P-AXIS-00490 | ||||
| Error type | 2, Error message by data transfer from parameter list into control device. | |||
| 
 | ||||