| Parameter P-AXIS-00803 can only be used for drive controlled homing. | ||||
| Description | The parameter kenngr.homing_without_drive_enable (P-AXIS-00803) can only be used with drive types that support drive-controlled homing. | |||
| Response | Class | 1 | Warning and correction of parameter. P-AXIS-00803 is set to zero. | |
| Solution | Class | 1 | Check the strategy for homing. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number (P-AXIS-00016) of axis effected. | ||||
| %2: | Current value [-] | |||
| Drive type used (P-AXIS-00020) of the axis. | ||||
| %3: | Error value [-] | |||
| Parameterised value of P-AXIS-00803. | ||||
| %4: | Corrected value [-] | |||
| Corrected value for P-AXIS-00803. | ||||
| Error type | 2, Error message by data transfer from parameter list into control device. | |||
| 
 | ||||